Look at almost any soundproofing product and you’ll find a rating on it. Rw 38. STC 45. NRC 0.90. They look similar, but they measure completely different things, and mixing them up is one of the easiest ways to buy the wrong product.
This guide explains what each acoustic rating means, which one matters for your problem, and what counts as a good number.
Two types of rating for two different jobs
Before getting into the letters, it helps to know that soundproofing ratings fall into two groups.
Sound blocking ratings (Rw and STC) measure how much sound is stopped as it tries to pass through something. These are the ratings that matter when noise is getting into a room from outside or from next door.
Sound absorption ratings (NRC) measure how much sound a surface soaks up instead of bouncing back into the room. These matter when a room sounds echoey, harsh or loud on its own.
A product can be excellent at one and poor at the other. A heavy board blocks a lot of sound but absorbs very little. A soft foam panel absorbs a lot but blocks very little.
If you want the fuller picture of how barriers and absorbers differ, Soundproofing 101 covers it
| Rating | What it measures | Better score | Where you’ll see it |
|---|---|---|---|
| Rw | How much sound a wall, floor, door or window stops from passing through | Higher | Australian and European spec sheets, the NCC |
| Rw + Ctr | The same, adjusted for low-frequency noise like traffic and bass | Higher | NCC requirements for apartments and townhouses |
| STC | How much sound a building element stops (the American equivalent of Rw) | Higher | Imported products, US websites and videos |
| NRC | How much sound a surface absorbs instead of reflecting | Higher (0 to 1) | Acoustic panels, ceiling tiles, foam |
| Ln,w | How much impact noise (like footsteps) comes through a floor | Lower | Flooring, underlays, floor systems |
What is an Rw rating?
Rw stands for weighted sound reduction index. It’s a single number, measured in decibels, that tells you how much sound a building element stops. The element might be a wall, a floor, a door, a window or a sheet material.
The rating comes from a laboratory test. Sound is played on one side of a test panel across a range of frequencies, and the level is measured on the other side. The results are then compared against a standard curve (set out in ISO 717-1, which Australia adopts) to produce one number. The higher the Rw, the more sound it blocks.
Rw is the rating used in the National Construction Code (NCC), on Australian spec sheets and by acoustic consultants here. If you’re comparing sound barrier products, walls or windows in Australia, Rw is the number to look at.
What is a good Rw rating?
It depends on what you’re trying to block, but this rough guide shows what different Rw ratings mean for a wall between two rooms where someone is talking on the other side:
| Rw | What you’d hear through the wall |
|---|---|
| 25 | Normal speech can be understood easily |
| 30 | Loud speech can be understood fairly well; normal speech is heard but harder to follow |
| 35 | Loud speech can be heard but not understood |
| 40 | Loud speech comes through as a murmur |
| 45 | You have to strain to hear loud speech |
| 50 | Loud speech is faint, if you can hear it at all |
Decibels don’t work like a normal scale. A 10 dB increase in Rw roughly halves how loud the noise sounds on your side. So moving from an Rw 40 wall to an Rw 50 wall is a big step up, not a small one.
As a general guide, internal walls in a home are often in the 30s and 40s. Walls between apartments need to be considerably better than that, which is where the NCC comes in.
What does Rw + Ctr mean?
You’ll often see Rw written with a second number, such as Rw 55, Ctr -6, or combined as Rw + Ctr 49. Ctr is an adjustment for low-frequency noise: traffic rumble, bass from a sound system, heavy machinery.
Low frequencies are harder to block than voices, so Ctr is almost always a negative number. That means Rw + Ctr is lower than Rw on its own. If your noise problem is traffic or music, Rw + Ctr gives you a more honest picture of how a product will perform.
Rw ratings and the NCC
The NCC sets minimum sound insulation levels for walls and floors between separate homes, such as apartments and attached townhouses. For walls between units, the requirement is generally Rw + Ctr of at least 50 for the construction. Floors between apartments also need to meet an impact noise limit, so footsteps don’t carry straight through.
These are minimums, not targets. Plenty of people living in compliant buildings still hear their neighbours. If you’re building or renovating, an acoustic consultant can tell you exactly which requirements apply to your project.
Lab ratings and real-world results
An Rw rating is measured in a lab under ideal conditions. Once a wall is built in a real home, the result on site is usually lower. Sound finds other paths around the wall, such as through the ceiling space, floor framing, gaps at the edges and power points. Acousticians call this flanking.
On-site results are measured with a different rating, DnT,w, which is why building reports sometimes show a different number from the product brochure. The practical lesson is simple: a high-rated product only performs as well as its installation. Gaps and weak points elsewhere in the room will drag the result down.
What is an STC rating?
STC stands for sound transmission class. It does the same job as Rw: one number that tells you how well a building element blocks sound. Higher is better.
The difference is where it comes from. STC is an American standard, so you’ll see it on imported products, US websites and a lot of YouTube content. It’s calculated from a slightly different frequency range and uses a different method from Rw.
Is STC the same as Rw?
Not exactly, but they’re close. For most common walls and materials, the two numbers land within a few points of each other. That makes STC useful as a rough guide when an imported product only lists STC.
What you can’t do is swap one for the other on paper. If you’re building to the NCC or a consultant has specified a performance level, the number needs to be an Rw from a proper test. An STC figure won’t meet an Rw requirement, even if the numbers look similar.
The US also has its own version of Ctr, called OITC (outdoor-indoor transmission class), which focuses on low-frequency outdoor noise like traffic and aircraft.
What is an NRC rating?
NRC stands for noise reduction coefficient. Despite the name, it has nothing to do with stopping noise passing through a wall. It measures how much sound a surface absorbs instead of reflecting back into the room.
NRC runs from 0 to 1:
- 0 means the surface reflects all the sound that hits it. Think glass, tiles or polished concrete.
- 1 means it absorbs essentially all of it.
The number is an average of how well the material absorbs sound at four frequencies across the range of the human voice, rounded to the nearest 0.05. That’s why NRC is the rating you’ll see on acoustic panels, ceiling tiles and foam.
For example, Ultra-Quiet Panels are rated NRC 0.90, while Stratocell Whisper and Fibertex are rated NRC 1.0. All three are designed to soak up sound and cut echo, which is exactly what NRC measures. You can compare the full range of sound absorbing panels by their NRC.
What is a good NRC rating?
For a product that’s meant to absorb sound, these are useful rough bands:
- Below 0.2: hard surfaces that reflect most sound.
- 0.2 to 0.5: soft furnishings and carpet. Helpful, but limited.
- 0.5 to 0.8: decent absorption. Fine for general rooms.
- 0.8 and above: high-performance acoustic panels. This is what you want for studios, home theatres, offices and noisy hospitality spaces.
So yes, an NRC of 0.8 is good. For dedicated acoustic treatment, 0.85 and above is where the better products sit.
Can an NRC rating be higher than 1?
Sometimes you’ll see a rating like 1.05 or 1.10. That doesn’t mean the material absorbs more than all the sound. It’s a quirk of the test method: the edges of the sample also absorb sound, which nudges the result over 1. In practice, treat anything at 1.0 or above as absorbing virtually everything that reaches it, at least in the frequencies NRC covers.
What NRC doesn’t tell you
Because NRC averages mid-range frequencies, it says little about bass. Two panels with the same NRC can behave very differently on low-frequency sound, and thickness makes a big difference. A thicker panel, or one mounted with an air gap behind it, generally handles lower frequencies better.
You may also see αw (weighted sound absorption coefficient), which is the European and Australian standard equivalent. It sits on the same 0 to 1 scale and is sometimes given as a class from A to E, with Class A being the most absorptive. If you’re weighing up panel types, our guide to acoustic panels and how to choose them goes into more detail.
A rating for footsteps: Ln,w
There’s one more rating worth knowing if you live in an apartment or a two-storey home. Ln,w measures impact noise, like footsteps, dropped objects and chairs scraping, coming through a floor. Unlike the others, lower is better, because it measures how much noise gets through rather than how much is stopped.
Flooring and underlay products sometimes list an improvement figure instead, written as ΔLw. A higher ΔLw means a bigger improvement. PhoneStar soundproofing board, for example, lists Rw 38 dB for airborne sound and ΔLw 22 dB for impact sound, which is why it’s used in floors and shared walls.
How to use acoustic ratings when you’re buying
Ratings are only useful if you compare the right ones.
A few simple rules will keep you on track:
- Match the rating to the problem. Noise coming in from outside or next door? Look at Rw. A room that sounds echoey? Look at NRC. Footsteps from above? Look at Ln,w or ΔLw.
- Compare like with like. An Rw on one product and an STC on another aren’t a fair comparison. Neither is the Rw of a single sheet against the Rw of a complete wall system.
- Check whether it’s the product or the system. Many Rw ratings apply to a full wall build, including studs, insulation and plasterboard. The product alone won’t hit that number.
- Remember the weakest point. A wall rated Rw 50 next to a hollow door or a single pane of glass will only perform as well as the door or window. That’s why noise so often comes through windows first.
- Be wary of ratings with no test behind them. A good spec sheet will tell you which standard the product was tested to.
The bottom line
Rw and STC tell you how well something blocks sound. NRC tells you how well it absorbs sound. Ln,w tells you how much impact noise gets through a floor. Work out what kind of noise problem you have first, then compare products using the rating that matches it.
If you’re still not sure which number matters for your project, the team at Soundproof Warehouse can talk you through the spec sheets and help you compare products on equal terms.
Frequently asked questions
What is a good Rw rating for a wall?
For an internal wall in a home, Rw 40 to 45 is a reasonable aim if you want voices to come through only as a murmur. Walls between separate homes need more, and the NCC requires at least Rw + Ctr 50 for walls between apartments.
Is an STC rating of 27 good?
It’s on the low side. At that level, normal speech will still come through quite clearly. It’s a figure you might see on a basic window or a light door, rather than a product designed for soundproofing.
Is NRC 0.8 good?
Yes. An NRC of 0.8 means the surface absorbs most of the sound that hits it, which is solid performance for acoustic panels. Dedicated acoustic products often sit between 0.85 and 1.0.
Does a higher NRC mean better soundproofing?
No. NRC measures absorption inside a room, not how much sound passes through a wall. A panel with an NRC of 1.0 will make a room much less echoey, but it won’t stop your neighbour’s TV. For that, you need a product with a good Rw.
Is Rw the same as STC?
They measure the same thing using different standards, and the numbers are usually close. In Australia, Rw is the rating used in the NCC, so use Rw wherever compliance matters.
What does Rw + Ctr mean?
It’s the Rw rating adjusted for low-frequency sound, such as traffic or bass. Because low frequencies are harder to block, Rw + Ctr is usually lower than Rw on its own and gives a more realistic picture for those types of noise.